Combustible Dust Testing

Laboratory testing to quantify dust explosion and reactivity hazards

Safety Data Sheets

Develop critical safety data for inclusion in SDS documents

Gas and Vapor

Laboratory testing to quantify explosion hazards for vapor and gas mixtures

UN-DOT
Classification of hazardous materials subject to shipping and storage regulations
Hydrogen
Testing and consulting on the explosion risks associated with devices and processes which use or produce hydrogen
Safety Data Sheets

Develop critical safety data for inclusion in SDS documents

Thermal Stability

Safe storage or processing requires an understanding of the possible hazards associated with sensitivity to variations in temperature

Adiabatic Calorimetry
Data demonstrate the consequences of process upsets, such as failed equipment or improper procedures, and guide mitigation strategies including Emergency Relief System (ERS) design
Reaction Calorimetry
Data yield heat and gas removal requirements to control the desired process chemistry
Battery Safety

Testing to support safe design of batteries and electrical power backup facilities particularly to satisfy UL9540a ed.4

Safety Data Sheets

Develop critical safety data for inclusion in SDS documents

Cable Testing
Evaluate electrical cables to demonstrate reliability and identify defects or degradation
Equipment Qualification (EQ)
Testing and analysis to ensure that critical equipment will operate under adverse environmental conditions
Water Hammer
Analysis and testing to identify and prevent unwanted hydraulic pressure transients in process piping
Acoustic Vibration
Identify and eliminate potential sources of unwanted vibration in piping and structural systems
Gas & Air Intrusion
Analysis and testing to identify and prevent intrusion of gas or air in piping systems
ISO/IEC 17025:2017

Fauske & Associates fulfills the requirements of ISO/IEC 17025:2017 in the field of Testing

ISO 9001:2015
Fauske & Associates fulfills the requirements of ISO 9001:2015
Dust Hazards Analysis
Evaluate your process to identify combustible dust hazards and perform dust explosion testing
On-Site Risk Management
On-site safety studies can help identify explosibility and chemical reaction hazards so that appropriate testing, simulations, or calculations are identified to support safe scale up
DIERS Methodology
Design emergency pressure relief systems to mitigate the consequences of unwanted chemical reactivity and account for two-phase flow using the right tools and methods
Deflagrations (Dust/Vapor/Gas)

Properly size pressure relief vents to protect your processes from dust, vapor, and gas explosions

Effluent Handling

Pressure relief sizing is just the first step and it is critical to safely handle the effluent discharge from an overpressure event

FATE™ & Facility Modeling

FATE (Facility Flow, Aerosol, Thermal, and Explosion) is a flexible, fast-running code developed and maintained by Fauske and Associates under an ASME NQA-1 compliant QA program.

Mechanical, Piping, and Electrical
Engineering and testing to support safe plant operations and develop solutions to problems in heat transfer, fluid, flow, and electric power systems
Hydrogen Safety
Testing and consulting on the explosion risks associated with devices and processes which use or produce hydrogen
Thermal Hydraulics
Testing and analysis to ensure that critical equipment will operate under adverse environmental conditions
Nuclear Safety
Our Nuclear Services Group is recognized for comprehensive evaluations to help commercial nuclear power plants operate efficiently and stay compliant
Radioactive Waste
Safety analysis to underpin decomissioning process at facilities which have produced or used radioactive nuclear materials
Adiabatic Safety Calorimeters (ARSST and VSP2)

Low thermal inertial adiabatic calorimeters specially designed to provide directly scalable data that are critical to safe process design

Other Lab Equipment and Parts for the DSC/ARC/ARSST/VSP2 Calorimeters

Products and equipment for the process safety or process development laboratory

FERST

Software for emergency relief system design to ensure safe processing of reactive chemicals, including consideration of two-phase flow and runaway chemical reactions

FATE

Facility modeling software mechanistically tracks transport of heat, gasses, vapors, and aerosols for safety analysis of multi-room facilities

Blog

Our highly experienced team keeps you up-to-date on the latest process safety developments.

Process Safety Newsletter

Stay informed with our quarterly Process Safety Newsletters sharing topical articles and practical advice.

Resources

With over 40 years of industry expertise, we have a wealth of process safety knowledge to share.

Recent Posts

Modeling of Spent Fuel Pool During Severe Accidents Using MAAP Code

Posted by Fauske & Associates on 03.26.15

By: Matthew Kennedy, Nuclear Engineer

The spent fuel pool is a plant system which provides cooling of full or partially irradiated fuel rods. 10 CFR Part 72 requires that spent fuel cladding be protected during storage against degradation that leads to gross ruptures. Nuclear fuel cladding has been shown to degrade and rupture at high storage temperatures; therefore assemblies are stored in a large pool of water until the assembly decay heat is low enough for packaging and transportation to an ultimate repository or temporary dry storage. Figure 1 provides a representative spent fuel pool with a checkerboard loading pattern. The checkerboard loading pattern is used to provide spacing of the relative hot and reactive assemblies (red) by placing the cooler (blue and yellow) assemblies or empty (white) rack locations in-between.

Top Down View of Checkerboard Pattern of a Representative Spent Fuel Pool

Recent industry events have shown that during beyond design basis accidents there is a potential for the fuel in the spent fuel pool to heat up, fail, and release radioactive material to the environment. With the current state of an ultimate fuel repository in question, in the US, many utilities have looked to temporary storage solutions of spent fuel. These temporary options include dry storage, expansion of current pool inventories, and or shipping of fuel to other reactor sites for temporary storage.

Dry fuel storage is expensive (construction, analysis, and licensing costs) and can only be used when the decay heat has been significantly reduced through radioactive decay. Therefore, this option is usually used as a last resort option for the temporary storage of spent nuclear fuel. A more efficient and less costly method of spent nuclear fuel storage is to expand the capacity of the current spent fuel pools. In order to expand the current pool inventories, many utilities have used the advancements in neutronic and thermal hydraulic models and calculations to refine earlier analysis. This has lead to the development of high density spent fuel pool racks. High density fuel racks allow for fuel to be stored closer, thereby increasing the number of assemblies which can be stored in the pool, without violating the criticality or temperature limits of the system.

Due to the recent industry events, several utilities have undertaken initiatives to understand how the fuel stored in the spent fuel pool would behave under a beyond design basis accident. Accidents in the spent fuel pool are different from accidents in the reactor due to the large thermal inertia in the spent fuel pool water and the lower initial decay heat in fuel assemblies. Additionally, transient analysis of the spent fuel pool is complicated by the fact that multiple fuel designs, power levels, and irradiation times are present in the stored nuclear fuel. The Modular Accident Analysis Program (MAAP), which is owned by the Electric Power Research Institute (EPRI) and developed and maintained by Fauske & Associates LLC, is a program which has the ability to model the transient response during severe accident scenarios in the spent fuel pool. This model includes the initial fuel heat up upon loss of cooling, zirc-air/steam oxidation phenomena, fuel melting, Molten CoreConcrete Interaction (MCCI), and fission product release. The spent fuel pool model was first included in MAAP5 Version 5.01 and has been continuously improved in later versions.

Figure 2 and Equation 1 provide a simplistic model of the calculations which are considered in the MAAP simulation. Figure 2 and Equation 1 show that the pool heat Qpool is determined by the radiation heat transfer (Qrad) from the uncovered portion on a fuel rod, the convection heat transfer (Qconv,steam & Qconv,H2O) for both the steam and water portions, and the heat loss terms due to pool boiling (Qboil), and the spent fuel pool cooling system (Qcooling). This figure and equation provide a simplified analysis of the overall phenomena which occur during a severe accident in the spent fuel pool.

Detailed view of Heat Transfer from a Single Spent Fuel Pool Rod

The MAAP spent fuel pool model has the ability to model transient and accident conditions which may occur in the spent fuel pool at nuclear reactor sites. The model also contains the ability to specify emergency cooling operations. These emergency operations can be either designed safeguards features or can be aligned under the sites emergency or FLEX strategies. Many utilities are interested in the timing of an accident mitigation system in order to prevent fission product release.

The following discussion provides a sample analysis of a loss of the spent fuel pool cooling system for an extended period for a hypothetical reactor site. The sample is a representative analysis for a spent fuel pool with 15 previous PWR batches (70-80 assemblies per batch) in addition to a full core offload (approximately 200 assemblies). This discussion provides some key metrics which may be evaluated during a severe accident. Figure 3 shows the decrease in the spent fuel pool water over the transient. This figure shows the decrease in the water level due to steaming until the water level is approximately zero (at approximately 150 hours), signifying that the entire inventory has been boiled off. Figure 4 shows the maximum fuel temperature over the transient for the same sequence. This figure shows that the fuel temperature is constant until the
water level reduces significantly. The fuel then rapidly increases in temperature due to the lack of cooling. This signifies that the spent fuel assemblies have become uncovered and the ability to cool the assemblies has been removed. The figure then shows a rapid decrease in the maximum spent fuel temperature, which corresponds to melting and relocation of the hottest fuel. A corium pool forms on the floor of the spent fuel pool and a phenomena known as Molten-Core Concrete Interaction (MCCI) begins. The maximum fuel temperature then increases because the older, lower decay power fuel, which did not heat up as quickly as the more recent, higher decay power, has a lack of cooling. This portion of the spent fuel then melts and adds to the corium pool on the floor which is seen by the second large decrease in the fuel temperature. The maximum temperature then reaches a constant value, slightly above zero, for the remainder of the sequence signifying that the entire pool inventory has melted and relocated to the floor of the spent fuel pool. The non-zero value corresponds to the default fuel temperature in the code once all of the fuel has been relocated from the core region. These two figures are just a sampling of the potential analysis potential which can be evaluated using the MAAP5 spent fuel pool model.

Spent Fuel Pool Water Level for a Hypothetical Loss of Spent Fuel Pool Cooling for an Extended Period

 

For further information, questions, or to inquire as to how Fauske & Associates, LLC can assist you in analysis of spent fuel or the spent fuel pool system please contact us at info@fauske.com.

 

Download as a PDF

 

Subscribe to FAI's "Nuclear Technical Bulletins"

Subscribe to FAI's Quarterly "Process Safety News"

cta-bg.jpg

Is My Dust Combustible?

A Flowchart To Help You Decide
Download Now